Data Logger Measurements view

The Data Logger Measurements view displays the values of the latest measurement extracted from the most recent data acquisition operation by the Data Logger module. This enables the user to get a rapid overview of the measurements being extracted from each geodetic sensor in the system.

Measurement entries are grouped by sensor type. For a detailed description of the columns of each sub-table see the following table. By default, all available columns are shown. To view a different selection of columns, right-click into the view; from its shortcut menu, select Choose Columns. Then edit the Choose Columns dialog.

Information on the data acquisition time

The information field on top of the view holds information on the date and time of the acquisition of the data.

Examples for groups based on sensor type

Group header

Description

Tilt

Available, when sensors with data type ‘Biaxial Tilt’ or ‘Uniaxial Tilt’ are added to the Data Logger module. Displays the latest tilt measurement for each individual tilt meter in decimal degrees of deflection from the initial reference measurement.

Temperature

Shows the latest temperature values as returned by all sensors measuring their internal temperature. In degrees Celsius.

Pressure

Available, when sensors with data type ‘Pressure’ are added to the Data Logger module. Displays the latest pressure measurement for each individual sensor in kilopascals.

Voltage

Displays the latest battery voltage returned by all sensors measuring their internal battery voltage. In Volts.

Columns in each table

Column

Description

More Information

Health

Icon visually describing the health status of the sensor.

The data set received for the last epoch is complete.

Some expected data is missing.

No data for this sensor in the data file.

Sensor Name

Sensor identification by its name.

Specified using the module properties.

Measurement

Measurement value.

Values are presented in SI units.

Sensor Failure Alarm

Has an alarm been issued?

One of the following:
On - The value is outside its accepted range. An alarm has been issued.
Off - The value is accepted. No alarm has been issued.

See Also

Data Logger Status view

Data Logger History view