The table of the Terrestrial Engine PP Reference Measurement view gives an overview of all fully surveyed points the module has found in any imported JobXML file. For a detailed description of the columns in the spreadsheet see the section below. The data displayed in the table is the data as measured in the first available round in the first file where the point has been fully surveyed.
Note - For a point to appear in the list, it must have been measured in both faces, forward and backward, during the site setup. If only one face is available, the point is discarded. The entries for disabled points are grayed out.
These measurements serve as reference for which the depending Integrity Monitor module can compute and visualize the current displacements. From these measurements the coordinates for the reference points have been calculated.
Column |
Description |
||
---|---|---|---|
Status icon |
Backsight points display a status icon. |
|
|
Point Name |
Target point name. Must be the same in the global point list. Each point must be measured in two faces to appear in the point list. |
||
Hz Circle Reading |
The horizontal angle between reference circle 0 and pointing direction. |
||
V Angle |
The vertical angle between total station and target. In degrees. |
||
EDM Distance |
Distance of the prism from the Electronic Distance Measurement device. |
||
Face |
One of either 1 or 2. |
||
Measurement Time |
Time of the measurement. |