The Enable/Disable Points dialog appears, if you do the following:
Use the dialog to enable or disable one or several points for being measured. You may also change the sequence in which the points are measured in the round.
When you first set up a Trimble 4D Control Server system and add a Data Collector module to the tree, this dialog will be empty. After a site setup for this mission, the dialog will display the configured target points. By default, all points are enabled.
Changes of the enabled/disabled status and/or the sorting order are immediately reflected in the Data Collector Site Setup dialog.
Tip - When adding a Data Collector module to the tree, this dialog may show points in the point list if the module had been added before or if another module configuration with the same mission name exists.
Temporarily disables the selected point(s), that is excludes it from the list of points to be measured in the rounds to come. Multiple selection using the Shift key is possible. In the list, disabled points are grayed out. Disabled points remain part of the point list of the site and keep their reference values. They will neither be processed nor respected for alarming, even if measurements are available.
Enables the selected, disabled point(s) for being measured in a round. Multiple selection using the Shift key is possible.
Use the arrow-up and arrow-down buttons to move the selected point to the preferred position in the sequence. You can only move one item at a time to a new location. In a round, the points are measured in the order they appear here from top to bottom.
Note - With a Data Receiver, the arrow buttons do not apply.