Terrestrial Engine RT - Processing rules

These rules apply for the Terrestrial Engine RT module when synchronizing the round measurements:

Sets of rounds missing or scheduled at different times

If, for example, Data Collector module A is scheduled to measure its set of rounds every hour, Data Collector module B, however, measures its set of rounds belonging to the same mission every 6 hours, it depends on the combination of these two properties and the measurement end times, how the measurements are combined in processing. See the table below, which displays the processing event times and the included set of roundss for selected Delay before processing and Maximum age of round settings for the daily time between 11:00 and 14:00 o'clock. All times shown here are in the time system you have selected for the Trimble 4D Control Server system.

Delay

Maximum age

End time of measurement Data Collector A (DCA)

End time of measurement Data Collector B (DCB)

Processing event time

Sets of rounds (DCA, DCB) included in processing

Comment

5 minutes

10 minutes

11:04;

12:04;
13:04;


12:03

- 11:09;

- 12:04;
- 13:09;

- DCA 11:04;

- DCA 12:04; DCB 12:03
- DCA 13:04;

Only once a day, the round measurements of the two Data Collector modules are processed in one.

5 minutes

10 minutes

11:04;
12:04;

13:04;



12:47

- 11:09;
- 12:09;
- 12:52;
- 13:09;

- DCA 11:04;
- DCA 12:04;
- DCB 12:47;
- DCA 13:04;

Each set of rounds is processed separately.

5 minutes

1 day


11:04;
12:04;

13:04;

(06:47)


12:47


- 11:09;
- 12:09;
- 12:47;
- 13:09;


- DCA 11:04; DCB 06:47
- DCA 12:04; DCB 06:47
- DCA 12:04; DCB 12:47
- DCA 13:04; DCB 12:47

The newest available round measurements of both Data Collector modules are always combined.

See Also

Data Collector: Input of real-time total station data

Terrestrial Engine RT Properties - General Settings