The Terrestrial Engine RT Status view gives an overview of the processing status for the latest measurements from all Data Collector modules the Terrestrial Engine RT module is connected to.
Above the table, there is information on the over-all synchronization status.
Synchronization Status: The present status of the processing engine. Possible states are: Waiting for the Data Collector modules to complete their rounds, Processing is started, and others.
Synchronization Timeout: A count-down of the time remaining until the next processing starts. The remaining time depends on the time the (scheduled) measurements of all participating Data Collector modules have been finished and the setting of the Delay before processing module property.
The data displayed in the table is the data as measured in the latest available set of rounds. One row in the table contains information referring to one Data Collector module, that means for one total station instrument. Data collector modules for which no site setup has been performed so far, do not show any synchronization status information. All times shown here are in the time system you have selected for the Trimble 4D Control Server system.
Column |
Description |
|
---|---|---|
Status icon |
Processing status of the Data Collector module: one of the following: |
|
|
Error, last set of rounds failed. |
|
|
Waiting for processing. Measured data has to be processed. |
|
|
Waiting for measurement. New measurements will be executed and arrive soon. |
|
Module Configuration |
The name of the Data Collector or Data Receiver module configuration. |
|
Serial Number |
Identification of the instrument by its serial number. |
|
Round Start Time |
Time when the first instrument in the system started to measure this set of rounds. |
|
Round End Time |
Time when the last instrument in the system finished to measure this set of rounds. |
|
Round Status |
The status of the last set of rounds. For example: |
|
Synchronization Status |
Status of the last set of rounds measured by this instrument, such as among others: |
|
Last Processed |
The most recent time when the data from this module was processed. Updated after each processing. |
The results displayed here are the last available measurements. To get displacements to the reference measurements and errors, make sure a Integrity Monitor module is added to the Terrestrial Engine RT. There, go to the Current Displacements module-view. The Displacement Chart module-view displays a history of measurements.
Tip - The default period to be displayed in the Integrity Monitor Displacement Chart view is 30 minutes. For many monitoring applications, it may be a good idea to increase the display period considerably, for example to weeks, months, or even years.