RTX-PP Engine Processing Status view

The RTX-PP Engine Status view gives you information on the current status of processing. It displays an overall summary on the current or following session.

Post Processing Session group

This group displays the period the next session to be processed covers and the remaining time until processing starts. If the time field displays the < 10 seconds value, the data is going to be processed. For actions, see the Processing Status group.

Processing Status group

The Processing Status group displays the current status of the RTX-PP Engine module. At session start time, the module performs the following and checks the respective list row after the tasks have been carried out:

Note - How often the progress bar updates depends on the bandwidth control setting you have selected when logging in to the Trimble 4D Control Server UI. If the bandwidth is controlled or restricted, the progress bar updates once for each station.

After processing, it lists the number of stations being processed. Possible reasons for a station to not being processed include the following:

The table of the RTX-PP Engine Status view gives an overview of the results of all stations the module has processed. The results include the fixing status and solution type. The view displays the current offsets (D) between the given and the processed station coordinates (displacements) in numerical form.

The elements shown in the table

Column

Description

More Information

Station Code

Unique station code

 

Status

Status message

 

Solution

No position

No solution possible. Server error message details the reason.

 

Fixed

 

Orbit

Broadcast, Predicted, or both (Mixed)

Indicates which orbit types are used for processing.

Epochs

Per session

Number of epochs used for processing.

D Northing, D Easting, D Height

In meters

Uni-directional distances to the known positions of the station.

D 3D

In meters

Three-dimensional distance to the known position of the station.

Note - The results of the RTX-PP Engine are displacements. To get station coordinates, displacements, and errors, add an Integrity Monitor module to the RTX-PP Engine. View the coordinates of fixed and adjusted (constrained) stations in its Current Displacements module-view.

See Also

RTX-PP Engine Properties - General Settings

RTX-PP Engine views